logo

Modular Water Cooled Water Chiller 220V 380V 415V 440V 480V Water Chiller Machine

1 units
MOQ
Discuss
Price
Modular Water Cooled Water Chiller 220V 380V 415V 440V 480V Water Chiller Machine
Features Gallery Product Description Request A Quote
Features
Specifications
Produce Name: Water Cooled Water Chiller
Throttling Device: Expansion Valve
Condenser Fans: Axial/Centrifugal
Condenser Fan Power: 16KW
Electric Parts: Schneider
Warranty: 1 Year
Water Flow: 9.48m3/h
Fan: 0.35KW*2PCS
Condenser Type: Air Cooled/Water Cooled
Control Of Refrigerant: Danfoss Expansion Valve
Tank Capacity: 70L
After Warranty Service: Video Technical Support
Evaporator: Shell And Tube
Cooling Way: Air Cooled/Water Cooled
Evaporator Type: Shell And Tube
Weight: Customized
Refrigerant Charge: 600Kg
Control System: Microcomputer
Pump: Horizontal/Vertical
Control: SCM Or PLC
Noise Level: 50-60dB
Function: Chilled Water
Product Type: Modular Type
Cooling Capacity: 10.2~156kw
Frequency: 50 Or 60HZ
Voltage: 220V/380V/415V/440V/480V
Highlight:

Modular Water Cooled Water Chiller

,

Water Cooled Water Chiller 220V

,

480V Water Chiller Machine

Basic Infomation
Place of Origin: CHINA
Brand Name: TOYOCOOL
Certification: ISO-9001,CE
Model Number: TOYOCOOL Water Chiller
Payment & Shipping Terms
Packaging Details: Wooden packaging
Delivery Time: 10-15DAYS
Payment Terms: L/C,T/T,D/P,D/A
Supply Ability: 100 units per month
Product Description

Water-Cooled Chillers 

Water-cooled chiller is a common industrial cooling equipment, mainly through the water cooling cooling industrial equipment or heat generated in the production process. It is mainly composed of condenser, evaporator, expansion valve and compressor, etc., through the cycle of working principle to achieve the cooling effect.

 

Water-cooled chillers are generally divided into two types: single-stage and multi-stage refrigeration. Single-stage refrigeration is mainly applicable to small refrigeration equipment, while multi-stage refrigeration can be applied to larger industrial refrigeration systems. The working principle of water-cooled chiller is to absorb heat by evaporating the work material in the evaporator, and then the evaporated gas will be cooled into liquid through the compressor, and then released through the expansion valve to continue the cycle.

 

 

 

Performance Features

- Efficient and precise temperature control:

 

Provide 5-35 ℃ water, precise adjustment of temperature ± 1 ℃; the use of high-efficiency shell and tube heat exchanger, high energy efficiency ratio; microcomputer precision intelligent control, with RS485 remote communication function.

 

- High-quality core parts:

 

Japan Panasonic or the United States Copeland compressor, low noise, high efficiency; with Toyo high-efficiency shell-and-tube condenser, coil or shell-and-tube evaporator, copper tube using internal and external threaded tube enhancement, enhanced heat transfer capacity, good cooling effect, evaporator cylinder body with insulation board insulation, no condensation, less loss of cold, smooth surface of the copper tube, easy to clean and maintain; the use of the United States ALCO, Denmark, Danish Danforth, and other international first-class brand accessories, excellent performance, safety and environmental protection; the microcomputer precision intelligent control with RS485 remote communication. Outstanding performance, safety and environmental protection; reliable operation and long service life of the unit; the shell adopts quick dismantling form, which is convenient for use and maintenance.

 

- Comprehensive safety protection:

 

With compressor delay start protector, compressor frequent start protector, compressor overheating protector, overload protector, high and low voltage protector, anti-freezing switch, fusible plugs, etc., to ensure the normal operation of the unit, with a lack of phase/reverse-phase protection, lack of water/insufficient flow protection, low temperature/anti-freezing protection and other functions.

 

- Widely used in the industry:

 

Applied in various industries such as injection moulding, plastic absorbing, electroplating, food, medicine, new materials and so on.

 

 

Water-cooled chiller parameter table

 

 

Note:

1. High-pressure pumps can be ordered according to customers' special requirements.

2. The above specifications are designed according to three-phase 380V/50HZ power supply.

3. If you need low-temperature type machine or acid and alkali resistant type, please specify before ordering.

4. The above products are designed according to standard, cooling water inlet 32℃, outlet 37℃, chilled water inlet temperature 12℃, outlet 5-7℃.

5. Product specifications are subject to change without notice.

 

 

 

Water-cooled chillers are widely used in different fields such as factories, hospitals, shopping malls, office buildings, electronic factories, etc. for cooling various equipment and machines. In the process of industrial production, high-temperature equipment may lead to overheating, which affects productivity and equipment life, and water-cooled chillers can effectively solve this problem and guarantee normal industrial production.

Recommended Products
Get in touch with us
Tel : 15012699306